VisualView HMI / SCADA Suported Drivers:
Allen Bradley / Rockwell Automation
A/B DF1 (Redundant - Hot Standby) PLC5, SLC500, SLC 5/01 - 5/05, MicroLogix  A/B Ethernet (Redundant - Hot Standby) ControlLogix, CompactLogix, FlexLogix A/B Ethernet PCCC (Redundant - Hot Standby) SLC, MicroLogix, SLC 5/05, PLC5 RSLinx not required

Automation Direct (DirectLogic, Koyo)
K-Sequence (Redundant - Hot Standby)
All register types

Bacnet/IP (Redundant - Hot Standby)
Analog Input, Analog Output, Analog Value, Binary Input, Binary Output,
Binary Value, Loop, Multi State Input, Multi State Output, Averaging,
Multi State Value, Life Safety Point, Life Safety Zone
Read Property, Write Property

Delta computer systems - motion controllers - Delta motion control protocol (DMCP)
TCP/IP and UDP/IP
Read and write all files and elements
Collect plots using Method 2 - Advanced (No limit on plot size)

Enron MODBUS
RTU (RS-232) and TCP/IP
RTU over TCP/IP
All register types

Fatek (Facon)
RS-232/485, TCP/IP and UDP/IP

General purpose serial port
Uses callbacks or polling scripts to control port

General purpose TCP/IP port
Uses callbacks or polling scripts to control port

GE SNP-X (Redundant - Hot Standby)
All register types
Long break or long break free

GE SRTP  (Redundant - Hot Standby)
All register types

IDEC (OpenNet) (Redundant - Hot Standby)
All register types

Keyence PLC (Redundant - Hot Standby)
All register types

Master-K LS/LG Industrial Systems  (Redundant - Hot Standby)

Mewtocol-COM (Panasonic/Matsushita/Aromat/NAIS) (Redundant - Hot Standby)

Mitsubishi FX 0,1,2,3 (Redundant - Hot Standby)
All register types
Bit, Word, Longword, Float

Mitsubishi Serial (Redundant - Hot Standby)
Protocol 3C, Format 1 or 4, Checksum or no checksum
All register types
Bit, Word, Longword, Float

Mitsubishi TCP/IP (Redundant - Hot Standby)
Protocol 3E
All register types
Bit, Word, Longword, Float

MODBUS/J-Bus Serial (RS-232/485) ASCII
Master
Bit, Float, String, Word

MODBUS/J-Bus Serial (RS-232) RTU (Redundant - Hot Standby)
Master and Slave
Bit, Float, String, Word

MODBUS/J-Bus Serial (RS-485) RTU
Master
Bit, Float, String, Word

MODBUS/J-Bus TCP/IP (Redundant - Hot Standby)
Master and Slave
Bit, Float, String, Word

Omron FINS (RS-232) (Redundant - Hot Standby)
C, CV or CS/CJ mode
All register types
Bit, Word, Longword, Float

Omron FINS (TCP and UDP) (Redundant - Hot Standby)
C, CV or CS/CJ mode
All register types
Bit, Word, Longword, Float, String

Omron Hostlink/SYSMAC-WAY (Redundant - Hot Standby)
All register types
Bit, Word, Longword, Float

Omni flow computers (Enron MODBUS) RS-232 and TCP
All register types
All report types

Saia-Burgess
Serial-S-Bus (RS232/485)
Ether-S-Bus
Registers, Counters, Timers, Flags, Inputs, Outputs, Data blocks
All data types - bit, integer, float, string

Siemens S7-200 (PPI) (Redundant - Hot Standby)

Siemens S7-200 (TCP/IP CP 243-1)

Inputs, Outputs, Analog Inputs, Analog Outputs, Variable memory, Timers, Counters, Special memory
All data types - bit, byte, word, double word, float, timer, counter, string

Siemens S7-300/400 (MPI) (Redundant - Hot Standby)
Inputs, Outputs, Internal memory, Timers, Counters
All data types - bit, byte, word, double word, float, timer, counter

Siemens S7-300/400/1200 (TCP) (Redundant - Hot Standby)

Inputs, Outputs, Internal memory, Timers, Counters, Data blocks
All data types - bit, byte, word, double word, float, timer, counter

SNMP (Simple Network Management Protocol) Version 1
UDP
Traps with logging
GetRequest/SetRequest

Toshiba ASCII computer link protocol (RS-232/485)
X, Y, R, S, T, C, D, L registers
Bit, Word, Longword, Float, String

Toshiba ASCII computer link protocol (UDP/IP)
X, Y, R, S, T, C, D, L registers
Bit, Word, Longword, Float, String