VisualView HMI / SCADA Suported Drivers:
Copyright 2026 by BLF-Tech LLC · All Rights reserved · E-Mail: bferry@blftech.com
Allen Bradley / Rockwell Automation
A/B DF1 (Redundant - Hot Standby) PLC5, SLC500, SLC 5/01 - 5/05, MicroLogix A/B Ethernet (Redundant - Hot Standby) ControlLogix, CompactLogix, FlexLogix A/B Ethernet PCCC (Redundant - Hot Standby) SLC, MicroLogix, SLC 5/05, PLC5 RSLinx not required
Automation Direct (DirectLogic, Koyo)
K-Sequence (Redundant - Hot Standby)
All register types
Bacnet/IP (Redundant - Hot Standby)
Analog Input, Analog Output, Analog Value, Binary Input, Binary Output,
Binary Value, Loop, Multi State Input, Multi State Output, Averaging,
Multi State Value, Life Safety Point, Life Safety Zone
Read Property, Write Property
Delta computer systems - motion controllers - Delta motion control protocol (DMCP)
TCP/IP and UDP/IP
Read and write all files and elements
Collect plots using Method 2 - Advanced (No limit on plot size)
Enron MODBUS
RTU (RS-232) and TCP/IP
RTU over TCP/IP
All register types
Fatek (Facon)
RS-232/485, TCP/IP and UDP/IP
General purpose serial port
Uses callbacks or polling scripts to control port
General purpose TCP/IP port
Uses callbacks or polling scripts to control port
GE SNP-X (Redundant - Hot Standby)
All register types
Long break or long break free
GE SRTP (Redundant - Hot Standby)
All register types
IDEC (OpenNet) (Redundant - Hot Standby)
All register types
Keyence PLC (Redundant - Hot Standby)
All register types
Master-K LS/LG Industrial Systems (Redundant - Hot Standby)
Mewtocol-COM (Panasonic/Matsushita/Aromat/NAIS) (Redundant - Hot Standby)
Mitsubishi FX 0,1,2,3 (Redundant - Hot Standby)
All register types
Bit, Word, Longword, Float
Mitsubishi Serial (Redundant - Hot Standby)
Protocol 3C, Format 1 or 4, Checksum or no checksum
All register types
Bit, Word, Longword, Float
Mitsubishi TCP/IP (Redundant - Hot Standby)
Protocol 3E
All register types
Bit, Word, Longword, Float
MODBUS/J-Bus Serial (RS-232/485) ASCII
Master
Bit, Float, String, Word
MODBUS/J-Bus Serial (RS-232) RTU (Redundant - Hot Standby)
Master and Slave
Bit, Float, String, Word
MODBUS/J-Bus Serial (RS-485) RTU
Master
Bit, Float, String, Word
MODBUS/J-Bus TCP/IP (Redundant - Hot Standby)
Master and Slave
Bit, Float, String, Word
Omron FINS (RS-232) (Redundant - Hot Standby)
C, CV or CS/CJ mode
All register types
Bit, Word, Longword, Float
Omron FINS (TCP and UDP) (Redundant - Hot Standby)
C, CV or CS/CJ mode
All register types
Bit, Word, Longword, Float, String
Omron Hostlink/SYSMAC-WAY (Redundant - Hot Standby)
All register types
Bit, Word, Longword, Float
Omni flow computers (Enron MODBUS) RS-232 and TCP
All register types
All report types
Saia-Burgess
Serial-S-Bus (RS232/485)
Ether-S-Bus
Registers, Counters, Timers, Flags, Inputs, Outputs, Data blocks
All data types - bit, integer, float, string
Siemens S7-200 (PPI) (Redundant - Hot Standby)
Siemens S7-200 (TCP/IP CP 243-1)
Inputs, Outputs, Analog Inputs, Analog Outputs, Variable memory, Timers, Counters, Special memory
All data types - bit, byte, word, double word, float, timer, counter, string
Siemens S7-300/400 (MPI) (Redundant - Hot Standby)
Inputs, Outputs, Internal memory, Timers, Counters
All data types - bit, byte, word, double word, float, timer, counter
Siemens S7-300/400/1200 (TCP) (Redundant - Hot Standby)
Inputs, Outputs, Internal memory, Timers, Counters, Data blocks
All data types - bit, byte, word, double word, float, timer, counter
SNMP (Simple Network Management Protocol) Version 1
UDP
Traps with logging
GetRequest/SetRequest
Toshiba ASCII computer link protocol (RS-232/485)
X, Y, R, S, T, C, D, L registers
Bit, Word, Longword, Float, String
Toshiba ASCII computer link protocol (UDP/IP)
X, Y, R, S, T, C, D, L registers
Bit, Word, Longword, Float, String
Triconex Trident/Tri-GP TSAA (UDP/IP)
All data types
Collect and log SOE data
WeMo
Insight switch, Maker, Switch and Light switch
Uses subscriptions for reduced network loading